Omni automation hai manual
Panic Switches If you have had panic switches installed, they are always armed. You may also have your heating and air conditioning HVAC under control of the system, which will allow you to save energy dollars by setting the temperature appropriately when you are home, asleep, or away.
Page Hai Lighting Control Hlc Format When set to UPB, the OmniLT controller can: Send commands on, off, bright, dim and level to individual switches and modules Receive commands and status from individual switches and modules Send commands to keypad controllers to change scenes and control LED backlight behind the keys Receive commands when buttons are pressed on keypad controllers to activate controller macros Send Link commands to switches, modules, and keypad controllers to activate scenes Receive Link commands when a button is pressed on a switch or on a keypad controller to activate controller macros Room Controllers also keep track of when individual switches in a room are turned on and off.
In general, any time you enter a unit, zone, button, code, temperature, or message number, you can press the down arrow key to display its name, then use the up and down arrow keys to scroll through the list of other names.
Timed commands may be from seconds, minutes or hours. Press the 5 RAMP key to select the ramp command. Page Status Of A Unit The timed commands allow a units to be turned on or off for a specified period of time. The unit may be turned On for minutes or seconds , or hours, then Off; or turned Off for minutes or seconds or hours, then On.
Lighting units may also be dimmed or brightened for a specified period of time. Outputs 1 and 2 are controlled by unit numbers 27 and These are hardwired outputs that are connected directly through the OmniLT and not through a module. If you have something connected to these outputs, such as a sprinkler system, your dealer will explain its operation. There are 16 Scenes that can be set and executed. The Leviton Switches are divided into "lighting groups" of four units each.
Each of these lighting groups can be set to four different Scenes. Notes: 1. When sending Scene Commands, the controller must be configured to allow Extended Code transmissions.
Page Temperature Control This powerful feature allows you to set your system up so that control functions are performed when you arm your security system such as turning off all lights and setting back the HVAC system.
Door contacts and motion detectors can be used to turn on lighting automatically, then turn it off a few minutes after the person has left, and then only if it's dark. Page 32 After the ' ' key is pressed, a menu appropriate for the type of temperature zone is shown.
For Celsius temperatures, press the ' ' key prior to entering the temperature to make the number negative. The Celsius temperature may also be specified in 0. Page 34 To set up your thermostat for use with the energy saver, set it in the appropriate mode and set the temperature to your preference. The PESM cannot turn it back on. For example, the ceiling fan can be programmed to come on if the temperature goes above the High temperature a programming example to set this up is shown in the Programming section.
Page Configuring Hlc Devices You may enter a unit number to start displaying the status of that unit, or simply press the down arrow key to scroll through the list of units. The status display is as shown under Control, except that now the arrow keys may be used to continue scrolling between units. Event Log The Event Log records the 50 most recent significant security system Events happenings and trouble conditions in the system.
When a new event occurs, the oldest one is lost. A remote phone access is when someone calls into the system from an outside phone line. Page 43 Pro-Link also has the capability to monitor the serial port for incoming text messages. When a text message is received, Pro-Link searches through all 16 messages for a matching message. If one is found, the Program Command macro corresponding to the matching message is activated. The OmniLT actually talks to you using a digital recording of an actual human voice, so the sound is incredibly life like.
If four invalid codes are entered, the system will hang up and a one-hour lockout period will begin. During the lockout period, the OmniLT will not answer a call after any number of rings, which should discourage the caller.
From an in-house phone, the dial tone will return. From a remote phone, you will hear a click as the OmniLT hangs up. It is recommended that you press 9 to terminate a remote call. Page Emergency Dial-Out Emergency Dial-Out Emergency dial out consists of two distinct parts: the "digital dialer" and the "voice dialer. The digital dialer sends a digitally coded message to the central station's receiver and computer.
The computer in the central station presents your name, address, and other information to a human operator who notifies the appropriate authorities. The dialer will wait up to 45 seconds after it finishes dialing a complete phone number for a voice to answer.
If it doesn't hear a voice in that time, it goes on to the next number. Page Setup High Security Mode, and have telephone access privilege. Telephone access is not a User privilege. Page Duress Code The system will disarm normally. To stop a silent dial out, turn your security system off by pressing OFF, then your code. Each program must specify when that program should execute and an action to be taken. The program may also specify a condition that must be true for the program to execute.
Page Delete All Programs Otherwise, a help screen is displayed: Press to delete or edit displayed program. The first program is displayed once the down arrow is pressed. The bottom line shows the command to execute when the program is activated.
You will be prompted to enter the day s that the program will be activated. Page Security Mode Event Buttons Press the 0 OFF key to select when the unit turns off or press the 1 ON key to select when the unit turns on this program is executed whenever the unit is turned off or on. Page Miscellaneous Event Buttons "Off" events will be activated whenever the selected device is turned off. If Remote Commands Ok is set to No, then lights, appliances, and the security system cannot be controlled from a remote telephone that dials into your home.
Page Dial Out Numbers The default entry delay is 15 seconds. If you wish to allow yourself more time to get in and turn off the security system, you may set the entry delay between 15 and 45 seconds.
Enable Quick Arm The Quick Arm feature allows the security system to be armed by pressing the desired mode key twice instead of having to enter your code. The default setting for Enable Quick Arm is No. Page Set Up Miscellaneous If your system is set up with High Security On, the display will request the Master or Manager code whenever you select one of these functions, even if the security system is Off.
Page Quick Arm If a fire zone is bypassed, the console will continue to beep until that zone is restored - See Restoring Zones. Auto-Bypass In order to prevent the alarm from sounding unexpectedly if a window or door is open when the system is armed, the Omni II will automatically bypass the zone if it is opened when the system is armed.
Page Goto The system waits the Dial Out Delay 0 - 60 seconds , then if programmed, the in-house phones are seized disconnected and the Omni II begins to dial out. If you are having your system monitored by a central station, the central station will be sent a code representing the type of alarm burglary and zone involved.
The console beeper stays on. If a zone is tripped after a reset, the sounder will again be activated, and the dialer will again dial out. Page Police Emergency Police Emergency When the 1 key and the 3 keys are pressed simultaneously, the Police Emergency alarm is activated.
Page Trouble Indications Codes There are 16 user codes that you may assign to users of the system. All Omni II codes are 4 digits in length. A code can be any number from to Each user should be assigned a security code with an authority level, areas that can be accessed if area arming is used , and times and days in which the code will be valid.
Page Manager Code If you have a code that is only valid in Area 1, you will not be able to disarm or arm Area 2. If you are in Area 1 and wish to disarm the security system in Area 2, Omni II will allow you to disarm Area 2 from the console in Area 1 if you have a Master code or a code that is valid for both areas.
If the Master code or a valid code is entered, the console will beep one time and Area 2 will be disarmed. Even if Auto Bypass is enabled, the system will not arm another area if any zones in that area are not ready. Pick up an inside phone and press the key. When the menu is spoken, press 8, Then 3. If it does, the telephone dialer, telephone access and telephone control systems are all working correctly. Page Control Control Commands The control features of the Omni II make it easy and convenient to control almost any light or appliance from the console or over the telephone.
You may also have your heating and air conditioning HVAC under control of the system, which will allow you to save energy dollars by setting the temperature appropriately when you are home, asleep, or away.
A House Code can have 16 unit numbers. The House Code is set on each module using a dial. House codes are letters A through P. Page Controlling Units The control menu is used when controlling lights and appliances.
To enter the control menu, from the top-level display or from the main menu, press the 1 CTRL key on the console keypad. Omni II will automatically display the first named item in that list. Page Ramp Command The console will beep and the lighting level will be adjusted. Outputs are controlled as Unit Numbers , respectively. If the Exterior Horn is configured as a "General Purpose" There are 64 Scenes that can be set and executed.
The Leviton Switches are divided into "lighting groups" of four units each. Each of these lighting groups can be set to four different Scenes. A Button also known as macro is a number on the keypad that is programmed to execute a series of commands when it is pressed. Buttons are used to program functions that are specific to your home and lifestyle. Page Temperature Control Press the ' ' key when the desired temperature zone is shown. Press the ' 0 ' key to select all HAI Thermostats.
This is a simple way to broadcast the new Heat or Cool setting or change the system mode, fan mode, or hold mode of all HAI thermostats in your system. A menu presenting options appropriate for that type of thermostat is then displayed. When you are away or asleep, the PESM can be set to allow the temperature to drift higher or lower to reduce the operating time, hence saving energy dollars.
Page Freeze Alarms After the ' ' key is pressed, a menu appropriate for the type of temperature zone is shown. For example, the ceiling fan can be programmed to come on if the temperature goes above the High temperature. The display is updated 3 times per second, although the actual readings are taken 10 times per second. Page Event Log The next series of displays shows the current analog reading for each security zone input.
The displays show the readings for zones If Zones are configured as Fire or Gas zone, normal readings are between 26 - 43 when secure.
The 4 SAY key allows the controller to say the selected voice message over a speaker. This voice message can be an audible reminder of special events and occasions.
Page 38 64 messages for a matching message. If one is found, the Program Command macro corresponding to the matching message is activated.
If Omni II does not hear the key within 5 seconds, it hangs up and does not listen in again until the next time you pick up your phone. If the Omni II hears any key other than the key while it is listening in, it disconnects itself immediately. Page Phone Access Denied - Remote Lockout If you press a key that is not on the current menu, you will hear 3 beeps and the menu will be repeated.
So that the Omni II does not tie up your phone, there is a 10 to 15 second time-out that starts after the Omni II stops talking. If it does not hear any numbers from your phone in 10 to 15 seconds after it stops talking, the Omni II will hang up. Page Control When bypassing and restoring a zone, if voice descriptions have been programmed, after a three-second delay, the system will begin reading from the list of zones.
If the ' ' key is pressed, Omni II will read the next three descriptions if programmed. The Omni II will read the 3 latest events. From an in-house phone, the dial tone will return. From a remote phone, you will hear a click as the Omni II hangs up. It is recommended that you press 9 to terminate a remote call. If you don't, the Omni II will hang up anyway after about 15 seconds. The voice dial-out feature of the Omni II is a sophisticated system that can notify you at the office, on vacation, on a pocket pager, or notify your neighbor, a relative, and in some cases, local authorities.
If your system is monitored by a central station, it will be notified first. Then the voice dialer will dial out to the numbers as described above. All Omni II security codes are 4 digits in length to Each user should be assigned a security code with an authority level, areas that can be accessed if area arming is being used , and times in which the code will be valid.
Page Duress Code This item is used to correctly calculate the times for sunrise and sunset.
0コメント